Certificate III in Fire Protection Control
This qualification covers installing, setting up, testing, fault finding, repairing and maintaining fire protection systems in commercial and industrial buildings. It includes fire detection and warning equipment, cabling and programming fire systems. If you already work on fire protection systems, your skills could be recognised through RPL.
- TRAINING PACKAGE
- UEE Electrotechnology
- ENTRY REQUIREMENTS
- Nil
- SUPERSEDES
- UEE31020 Certificate III in Fire Protection Control (equivalent)
WHO IT'S FOR
People who install, program or service fire detection and warning systems and want a formal qualification for that work.
TYPICAL JOB ROLES
- Fire protection technician
- Fire alarm technician
- Fire systems installer
- Fire services technician
Qualification structure
A total of 1060 weighting points comprising: 650 core weighting points listed below; plus 410 general elective weighting points from the general elective units listed below. Choose a total of 410 weighting points elective units from the list below, of which between 0 and 170 weighting points can be taken from Group A; and between 260 and 410 weighting points must be taken from Group B; or all minimum 410 weighting points can be taken from Group B. Up to 170 weighting points of the general elective units Group A, may be selected, with appropriate contextualisation, from any relevant nationally endorsed Training Package or accredited course, provided selected units contribute to the vocational outcome of the qualification. If weighting points are not listed for an imported unit in any other UEE qualification, default weighting will be 10 points. There are units of competency within this qualification that contain pre-requisites. Units of competency that have a pre-requisite requirement are identified by this symbol *. Refer directly to the units of competency to identify pre-requisite requirements to ensure all are complied with. A list of all pre-requisites is also provided in the UEE Pre-requisite Companion Volume. Where imported units are selected, care must be taken to ensure all pre-requisite units specified are complied with.
Core units
16 units- UEECD0007Apply work health and safety regulations, codes and practices in the workplace
- UEECD0016 (has a prerequisite)Document and apply measures to control WHS risks associated with electrotechnology work
- UEECD0019 (has a prerequisite)Fabricate, assemble and dismantle utilities industry components
- UEECD0020 (has a prerequisite)Fix and secure electrotechnology equipment
- UEECD0025 (has a prerequisite)Lay wiring/cabling and terminate accessories for extra- low voltage (ELV) circuits
- UEECD0043 (has a prerequisite)Solve problems in direct current circuits
- UEECD0045 (has a prerequisite)Solve problems in multiple path extra-low voltage (ELV) a.c. circuits
- UEECD0051 (has a prerequisite)Use drawings, diagrams, schedules, standards, codes and specifications
- UEECO0027Engage in communications, security equipment or fire protection work and competency development
- UEEDV0005 (has a prerequisite)Install and maintain cabling for multiple access to telecommunication services
- UEEEC0026 (has a prerequisite)Enter and verify programs for fire protection systems
- UEEEC0041 (has a prerequisite)Install fire detection and warning system apparatus
- UEEEC0060 (has a prerequisite)Repairs basic electronic apparatus faults by replacement of components
- UEEEC0076 (has a prerequisite)Verify compliance and functionality of fire protection system installations
- UEERE0001Apply environmentally and sustainable procedures in the energy sector
- CPPFES2043Apply regulations to prevent ozone depleting substance and synthetic greenhouse gas emissions
This unit has a prerequisite unit. Check the unit on training.gov.au for details.
Elective units
24 unitsGroup A: Imported and common elective units.
- BSBOPS203Deliver a service to customers
- CPCWHS1001Prepare to work safely in the construction industry
- HLTAID009Provide cardiopulmonary resuscitation
- HLTAID011Provide First Aid
- ICTICT214Operate application software packages
- UEECD0011Comply with scheduled and preventative maintenance program processes
- UEECD0035Provide basic instruction in the use of electrotechnology apparatus
- UEECO0002Maintain documentation
- UEECO0015Provide quotations for installation or service jobs
- UEECO0017Source and purchase material/parts for installation or service jobs
Group B: Qualification elective units.
- UEECS0033Use engineering applications software on personal computers
- UEEDV0006 (has a prerequisite)Install and modify optical fibre performance data communication cabling
- UEEDV0008 (has a prerequisite)Install, modify and verify coaxial and structured communication copper cabling
- UEEEC0008 (has a prerequisite)Commission large fire protection systems
- UEEEC0071 (has a prerequisite)Troubleshoot fire protection systems
- UEEEC0075 (has a prerequisite)Troubleshoot single phase input d.c power supplies
- UEEIC0002 (has a prerequisite)Assemble, enter and verify operating instructions in microprocessor equipped devices
- UEEIC0013 (has a prerequisite)Develop, enter and verify discrete control programs for programmable controllers
- UEEHA0004Enter a classified hazardous area to undertake work related to electrical equipment
- UEEHA0022 (has a prerequisite)Determine the explosion-protection requirements to meet a specified classified hazardous area
- UEEHA0025 (has a prerequisite)Install explosion-protected equipment and associated apparatus and wiring systems
- UEEHA0026 (has a prerequisite)Maintain equipment associated with hazardous areas
- UEERL0004 (has a prerequisite)Disconnect - reconnect electrical equipment connected to low voltage (LV) installation wiring
- UEERL0005 (has a prerequisite)Locate and rectify faults in low voltage (LV) electrical equipment using set procedures
This unit has a prerequisite unit. Check the unit on training.gov.au for details.
PREREQUISITES
- UEECD0019 Fabricate, assemble and dismantle utilities industry components — prerequisite: UEECD0007 Apply work health and safety regulations, codes and practices in the workplace
- UEECD0043 Solve problems in direct current circuits — prerequisite: UEECD0007 Apply work health and safety regulations, codes and practices in the workplace
- UEECD0051 Use drawings, diagrams, schedules, standards, codes and specifications — prerequisite: UEECD0007 Apply work health and safety regulations, codes and practices in the workplace
- UEEDV0006 Install and modify optical fibre performance data communication cabling — prerequisite: UEEDV0005 Install and maintain cabling for multiple access to telecommunication services; UEECD0007 Apply work health and safety regulations, codes and practices in the workplace; UEECD0051 Use drawings, diagrams, schedules, standards, codes and specifications; UEECD0019 Fabricate, assemble and dismantle utilities industry components; UEECD0020 Fix and secure electrotechnology equipment
- UEECD0045 Solve problems in multiple path extra-low voltage (ELV) a.c. circuits — prerequisite: UEECD0043 Solve problems in direct current circuits; UEECD0007 Apply work health and safety regulations, codes and practices in the workplace; UEECD0046 Solve problems in single path circuits; UEECD0044 Solve problems in multiple path circuits
- UEEEC0076 Verify compliance and functionality of fire protection system installations — prerequisite: UEECD0007 Apply work health and safety regulations, codes and practices in the workplace; UEECD0051 Use drawings, diagrams, schedules, standards, codes and specifications; UEECD0019 Fabricate, assemble and dismantle utilities industry components; UEECD0020 Fix and secure electrotechnology equipment; UEEEC0041 Install fire detection and warning system apparatus
- UEEEC0041 Install fire detection and warning system apparatus — prerequisite: UEECD0007 Apply work health and safety regulations, codes and practices in the workplace; UEECD0051 Use drawings, diagrams, schedules, standards, codes and specifications; UEECD0019 Fabricate, assemble and dismantle utilities industry components; UEECD0020 Fix and secure electrotechnology equipment
- UEEHA0025 Install explosion-protected equipment and associated apparatus and wiring systems — prerequisite: UEEHA0022 Determine the explosion- protection requirements to meet a specified classified hazardous area; UEEHA0004 Enter a classified hazardous area to undertake work related to electrical equipment
- UEEDV0008 Install, modify and verify coaxial and structured communication copper cabling — prerequisite: UEECD0043 Solve problems in direct current circuits; UEEDV0005 Install and maintain cabling for multiple access to telecommunication services; UEECD0007 Apply work health and safety regulations, codes and practices in the workplace; UEECD0046 Solve problems in single path circuits; UEECD0051 Use drawings, diagrams, schedules, standards, codes and specifications; UEECD0019 Fabricate, assemble and dismantle utilities industry components; UEECD0020 Fix and secure electrotechnology equipment; UEECD0044 Solve problems in multiple path circuits
- UEEIC0013 Develop, enter and verify discrete control programs for programmable controllers — prerequisite: UEECD0007 Apply work health and safety regulations, codes and practices in the workplace
- UEERL0004 Disconnect - reconnect electrical equipment connected to low voltage (LV) installation wiring — prerequisite: UEECD0007 Apply work health and safety regulations, codes and practices in the workplace
- UEEEC0075 Troubleshoot single phase input d.c power supplies — prerequisite: UEEEL0021 Solve problems in magnetic and electromagnetic devices; UEEEC0065 Solve problems in basic electronic circuits; UEECD0043 Solve problems in direct current circuits; UEECD0007 Apply work health and safety regulations, codes and practices in the workplace; UEECD0046 Solve problems in single path circuits; UEEEC0060 Repairs basic electronic apparatus faults by replacement of components; UEEEL0020 Solve problems in low voltage a.c. circuits; UEECD0019 Fabricate, assemble and dismantle utilities industry components; UEEEC0074 Troubleshoot resonance circuits in an electronic apparatus; UEECD0045 Solve problems in multiple path extra-low voltage (ELV) a.c. circuits; UEEEL0019 Solve problems in direct current (d.c.) machines; UEECD0044 Solve problems in multiple path circuits
- UEEEC0071 Troubleshoot fire protection systems — prerequisite: UEEEC0008 Commission large fire protection systems; UEEEC0026 Enter and verify programs for fire protection systems; UEEEC0076 Verify compliance and functionality of fire protection system installations; UEECD0007 Apply work health and safety regulations, codes and practices in the workplace; UEECD0051 Use drawings, diagrams, schedules, standards, codes and specifications; UEECD0019 Fabricate, assemble and dismantle utilities industry components; UEECD0020 Fix and secure electrotechnology equipment; UEEEC0041 Install fire detection and warning system apparatus
- UEEEC0008 Commission large fire protection systems — prerequisite: UEEEC0026 Enter and verify programs for fire protection systems; UEEEC0076 Verify compliance and functionality of fire protection system installations; UEECD0007 Apply work health and safety regulations, codes and practices in the workplace; UEECD0051 Use drawings, diagrams, schedules, standards, codes and specifications; UEECD0019 Fabricate, assemble and dismantle utilities industry components; UEECD0020 Fix and secure electrotechnology equipment; UEEEC0041 Install fire detection and warning system apparatus
- UEEHA0022 Determine the explosion- protection requirements to meet a specified classified hazardous area — prerequisite: UEEHA0004 Enter a classified hazardous area to undertake work related to electrical equipment
- UEEHA0026 Maintain equipment associated with hazardous areas — prerequisite: UEEHA0022 Determine the explosion- protection requirements to meet a specified classified hazardous area; UEEHA0004 Enter a classified hazardous area to undertake work related to electrical equipment
- UEEDV0005 Install and maintain cabling for multiple access to telecommunication services — prerequisite: UEECD0043 Solve problems in direct current circuits; UEECD0007 Apply work health and safety regulations, codes and practices in the workplace; UEECD0046 Solve problems in single path circuits; UEECD0051 Use drawings, diagrams, schedules, standards, codes and specifications; UEECD0019 Fabricate, assemble and dismantle utilities industry components; UEECD0020 Fix and secure electrotechnology equipment; UEECD0044 Solve problems in multiple path circuits
- UEEEC0026 Enter and verify programs for fire protection systems — prerequisite: UEEEC0076 Verify compliance and functionality of fire protection system installations; UEECD0007 Apply work health and safety regulations, codes and practices in the workplace; UEECD0051 Use drawings, diagrams, schedules, standards, codes and specifications; UEECD0019 Fabricate, assemble and dismantle utilities industry components; UEECD0020 Fix and secure electrotechnology equipment; UEEEC0041 Install fire detection and warning system apparatus
- UEEIC0002 Assemble, enter and verify operating instructions in microprocessor equipped devices — prerequisite: UEECD0007 Apply work health and safety regulations, codes and practices in the workplace
- UEECD0020 Fix and secure electrotechnology equipment — prerequisite: UEECD0007 Apply work health and safety regulations, codes and practices in the workplace
- UEECD0025 Lay wiring/cabling and terminate accessories for extra-low voltage (ELV) circuits — prerequisite: UEECD0007 Apply work health and safety regulations, codes and practices in the workplace; UEECD0051 Use drawings, diagrams, schedules, standards, codes and specifications; UEECD0020 Fix and secure electrotechnology equipment
- UEERL0005 Locate and rectify faults in low voltage (LV) electrical equipment using set procedures — prerequisite: UEERL0004 Disconnect - reconnect electrical equipment connected to low voltage (LV) installation wiring; UEECD0007 Apply work health and safety regulations, codes and practices in the workplace
- UEECD0016 Document and apply measures to control WHS risks associated with electrotechnology work — prerequisite: UEECD0007 Apply work health and safety regulations, codes and practices in the workplace
- UEEEC0060 Repairs basic electronic apparatus faults by replacement of components — prerequisite: UEECD0007 Apply work health and safety regulations, codes and practices in the workplace; UEECD0019 Fabricate, assemble and dismantle utilities industry components
EVIDENCE YOU'LL NEED
- Resume showing your work history
- Reference letters from employers
- Photos or videos of jobs you've done
- Payslips or employment contracts
LICENSING
No licensing, legislative or certification requirements apply to this qualification at the time of publication.
View on training.gov.au(opens in a new tab)